直列4孔 50ml离心管磁力架

Cat. QYM504

产品描述:

启研4孔50ml离心管磁力架用于磁珠法分离样品。磁珠可用于分离细胞,蛋白,核酸,或其他生物样品。首先将磁珠与样品以适当的比例在离心管中混合。数分钟内,磁珠即可与样品中目的分子或细胞结合。之后将离心管放置在架子上,在磁力作用下,与磁珠结合的目的分子或细胞可随磁珠吸附在管壁上。弃上清,即可获得纯化的目标分子或细胞。当外加磁场移除后,磁珠即分散,不会残留磁性。启研磁力架可用于任何种类的磁珠分离。

 

产品特色:

规格:完美适配50ml尖底和圆底离心管,侧向吸附。

工作体积:10-45ml。

单排简约风格,操作简单,适合大量样品的有效磁珠分离。可同时分离4个样品。

室温储存。-20℃-70℃之间保持性能稳定。

磁铁可提供20Kg以上的垂直拉力,表磁大于4800gauss。

 

清洁与消毒:

可用75%酒精或1%次氯酸钠消毒。消毒后及时擦干。不可浸泡于水或其他有机溶剂中。

提示:请勿高压灭菌。

 

保存与稳定性:

磁力架包含强力钕磁铁部件,其磁性可维持终身不会消退。建议保存于凉爽、干燥环境,避免生锈。请勿在超过70℃(122℉)的环境下使用。避免暴露于外加磁场下。避免日光或紫外灯直射,因UV会使其表面变脆弱。

 

警告:

磁力架包含强磁场,使用时远离钢铁器具。佩戴心脏起搏器或其他医疗磁场装置者请勿使用。

 

Quayad(启研)Magnetic Separator Rack of 50ml centrifuge tubes(straight 4-well)

Cat. QYM504

●Holds:50ml pointed-bottom/round-bottom centrifuge tubes; Lateral adsorption.

●Working volume:10-45ml

●Simple single-row style, simple operation, suitable for effective magnetic bead separation of a large number of samples. The Rack can take up to 4 samples at the same time.

●Store at ambient temperature, and temperature range that can be subjected to -20-70°C.

●Magnetic bead suction more than 20kg; Surface gauss greater than 4800 gs.

 

Product Description

The Magnetic Separator Rack of 50ml centrifuge tube is used for sample separation by magnetic bead method. The magnetic beads can be used to isolate cells, proteins, nucleic acids or other biomolecules. The magnetic beads are mixed with the sample in the proper ratio in a centrifuge tube, and usually bind to the target biomolecules within a few minutes. The centrifuge tube is placed on the shelf, and the target molecule or cell combined with the magnetic bead can be adsorbed on the tube wall with the magnetic bead under the action of magnetic force. Discard the supernatant and obtain the target molecule or cell captured by the magnetic bead. After repeated adsorption and elution, the target biological samples can be separated and purified. When the magnetic field is removed, the magnetic beads are dispersed and no residual magnetism. These magnets can be used with all types of magnetic beads.

 

Precautions

These magnets contain very strong permanent magnets. People wearing a pacemaker or any other medical magnetized implant should not use this product unless advised by a health professional; the implant could be affected or damaged by exposure to a strong magnetic field. Keep tools and objects that could be damaged by the magnetic field out of the working area. This includes, but is not restricted to, credit cards and other products containing magnetic recording devices. Keep away from delicate instruments, watches, electronic equipment, displays and monitors. The magnet may attract steel or other magnetic material with high mechanical forces. Take care during handling. Avoid contact between two magnets. Do not pull the magnets apart if contact has been made; twist off to prevent damage to the unit or fingers.

 

Cleaning and Disinfection

The following materials are recommended for cleaning purposes. Spray and/or wipe the magnetic rack either with 70% alcohol, or 1% sodium hypochlorite solution (bleach). Dry promptly after disinfection. Do not submerge in aqueous solutions and avoid prolonged exposure to water orother organic solvents.

 

Note: Do not autoclave the magnetic.

 

Storage and stability

The magnets contain high-energy Neodymium permanent magnets, and the magnetic strength will not diminish significantly during the lifetime of the product. Do not use the magnets above 70°C (122°F) and store in a cool, dry environment. Avoid prolonged exposure of the magnets to direct sunlight or artificial UV light as the surface material may become brittle.

  